Technical Specification
B.5.3.2 High Speed Data over Ethernet
This connector is located at the back of the unit using the RJ-45 Ethernet port and is
enabled through the license key (RX1290/SWO/HSETHER).
Table B.26 High Speed Data Over Ethernet Connector
Item Specification
Safety status SELV
Connector Type RJ-45 (100BaseT)
Connector designation 10/100BaseT
Data rates (bit/s) 5 Mbps
Standards ETSI EN 301 192 v.1.2.1 (1999-06), Section 4
De-encapsulation type Data-Piping (Proprietary)
B.5.4 SNMP Remote Control Connector
Table B.27 SNMP Control Connector
Item Specification
Safety status SELV
Connector type RJ-45 (100BaseT)
Connector designation 10/100BaseT
Standard Ericsson SNMP Control MIB
B.5.5 Alarm Connector
Table B.28 Relay Alarm Output Specification
Item Specification
Safety status SELV
Connector type 9-way D-type female
Connector designation: ALARM
Contact Configuration SPDT (Change-over)
All volt-free contacts, fully isolated.
Contact Rating 1 A at 24 V DC
1 A at 50 V AC
Maximum Switching Current 1 A
Maximum Switching Voltage 50 Vdc / 30 V AC