Ericsson Internal
PRODUCT SPECIFICATION 5 (5)
Prepared (also subject responsible if other) No.
MICMALE 2/1301-BMR 603 1203/1 Uen
Approved Checked Date Rev Reference
EAB/FJB/GKF (Natalie Johansson) (MICANWO)
2008-09-05 D
Output Load Transient Response, Vo2 Output Load Transient Response, Vo3
Output voltage response to load current step-
change, output 2 (30mA-60mA-30mA)
dI/dt=0,01A/us
T
ref
=+25°C, V
I
= 53 V I
O
1 =8mA, Io3=80mA.
Top trace: output voltage 2 (500 mV/div.).
Mid trace: output voltage 3 (500 mV/div.).
Bottom trace: load current (20 mA/div.).
Time scale: (0.1 ms/div.).
Output voltage response to load current
step-change, output 3 (30mA-60mA-30mA)
dI/dt=0,01A/us
T
ref
=+25°C, V
I
= 53 V I
O
1 =8mA, Io2=50mA.
Top trace: output voltage 2 (200 mV/div.).
Mid trace: output voltage 3 (200 mV/div.).
Bottom trace: load current (20 mA/div.).
Time scale: (0.1 ms/div.).
E
BMR 603 1203/1
DC/DC converters, Input 40-72 V, Output 78/-52/-33 V/32W
EN/LZT 146 393 R1E September 2008