Ericsson 1553-FGC 101 1010 Uen A Instruções de Operação Página 150

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 149
HD H.264 Encoder Module
SD MPEG2 VCM Alarms - EN8100 and EN7100
The following table lists the alarm and failure identifiers generated by the SD MPEG2 VCM.
Audio8 Input Lock
Audio Module
Slot 3
0 000C00B2
786610
input Please check source connection.
Audio8 ADS
Control Track
Audio Module
Slot 3
0 000C00B3
786611
input
Control track for Audio Description not
present
Audio8 silence Audio Module
Slot 3
0 000C00B4
786612
input
Silent period detected. Valid only for
Audio Description Service encoding.
Audio8 loss of
metadata
Audio Module
Slot 3
0 000C00B5
786613
input
Metadata input lost and encoder set to
stop encoding on loss.
Name Module Slot Port
ID (hex) ID (dec)
Type Description
Over Temperature
Warning
EN8190
Encoder
Module
Slot 4
0 000D0001
851969
internal
Failure to take action may cause permanent
damage to the chassis. Please check the
fans are working correctly, and that th
eambient temperature is not excessive.
Over Temperature
EN8190
Encoder
Module
Slot 4
0 000D0002
851970
internal
Failure to take action may cause permanent
damage to the chassis. Please switch off
and refer to Customer Support.
Invalid Parameter
EN8190
Encoder
Module
Slot 4
0 000D0003
851971
internal
Invalid Parameter received by the
Video/Audio Module. Please see Video
Encoder status for a more detailed
description of the error.
Video/Audio
Module Error
EN8190
Encoder
Module
Slot 4
0 000D0004
851972
internal
Video/Audio Module Error. Please see Video
Encoder status for a more detailed
description of the error.
Power On Self Test
Failure
EN8190
Encoder
Module
Slot 4
0 000D0006
851974
internal
At least one start-up test has failed.
Problems may be experienced with the
normal operation of the chassis.
Internal HW
Information
EN8190
Encoder
Module
Slot 4
0 000D0007
851975
internal
HW reported an unexpected status value.
This does not effect normal operation of the
chassis.
Option Card Build
Version Mismatch
EN8190
Encoder
Module
Slot 4
0 000D0008
851976
internal
The software on this option card is not an
officially released version.
SMPTE334 Closed
Captions Input
Lock
EN8190
Encoder
Module
Slot 4
1 000D0009
851977
input
No valid SMPTE334 Closed Captions can be
detected
Video DSP Not Alive
EN8190
Encoder
Module
Slot 4
1 000D000A
851978
internal Video DSP alive count not incremented
Failed to Configure
Device
EN8190
Encoder
Module
Slot 4
1 000D000B
851979
internal FPGA load failed
Unexpected Values
in Debug Registers
EN8190
Encoder
Module
Slot 4
1 000D000C
851980
internal See logs for further information
Name
Module Slot Port ID (hex)
ID
(dec)
Type Description
Over
Temperature
Warning
MPEG2
Video
Coding
Module
Slot n
0 000A0001 655361
internal
Failure to take action may cause
permanent damage to the chassis.
Please check the fans are working
correctly, and that th eambient
temperature is not excessive.
Over
MPEG2
Video
Slot n
0 000A0002 655362
internal
Failure to take action may cause