3.10 Setting Up the Alarms (Menu 6)
Menu 6 allows a selection of Alarms to be edited.
Table 3.21: Setting up the Alarms
Step Action Result
1 Go to Menu 6. Accesses the Alarms menu.
2 Scroll to Menu 6.6 and edit the BIT ERROR
RATE range (9.9 E-1 to 1.0 E-8) and status
(NO ALARM, SET ALARM ONLY). Press
Save.
Edits the BER alarms menu.
3 Scroll to Menu 6.1 and edit the TRANSPORT
STREAM menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the Transport Stream alarms menu.
4 Scroll to Menu 6.2 and edit the VIDEO menu
(NO ALARM, SET ALARM ONLY). Press
Save.
Edits the Video alarms menu.
5 Scroll to Menu 6.3 and edit the
AUDIO 1 menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the Audio 1 alarms menu.
6 Scroll to Menu 6.4 and edit the
AUDIO 2 menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the Audio 2 alarms menu.
7 Scroll to Menu 6.5 and edit the
AUDIO 3 menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the Audio 3 alarms menu.
8 Scroll to Menu 6.6 and edit the
AUDIO 4 menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the Audio 4 alarms menu.
9 Scroll to Menu 6.7 and edit the
MER menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the MER Error Rate (00.0 to 69.9) and status menu.
10 Scroll to Menu 6.8 and edit the
BER menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the BER Error Rate (00.0 to 69.9) and status menu.
11 Scroll to Menu 6.9 and edit the
EBNO menu (NO ALARM, SET ALARM
ONLY). Press Save.
Edits the EBNO
12 Scroll to Menu 6.10 and edit the
TEMPERATURE menu (NO ALARM, SET
ALARM ONLY). Press Save.
Edits the Temperature menu.