Appendix
RX8200 Configuration Guide
Figure 44 RX8200 Alarm Menu
Compatibility Vs Dynamic Mode Alarms
The current dynamic mode alarm functionality utilizes the next available incrementing identifier assigned at start-up.
These identifiers will change depending on the cards present in the unit configuration. The compatibility mode setting
allows pre-defined fixed identifiers to be assigned at startup. This in-turn allows the identifier of different units to be
tracked through the external control system consistently
Input
No TS Lock – Choose the alarm condition from the drop-down menu to be activated when Transport Stream loses
lock (Set Alarm /No Alarm).
No TS Lock (relay mapping) – Select the checkbox to activate relay mapping for Transport Stream loss of lock
alarm.
No Primary Input Lock – Choose the alarm condition from the drop-down menu to be activated when Primary Input
loses lock (Set Alarm /No Alarm).
No Primary Input Lock (relay mapping) – Select the checkbox to activate relay mapping for Primary Input loss of
lock alarm.
Monitor Inactive Input – Select the checkbox to activate an alarm when there is no signal present at the Primary
Input .
No Secondary Input Lock – Choose the alarm condition from the drop-down menu to be activated when Secondary
Input loses lock (Set Alarm /No Alarm).
No Secondary Input Lock (relay mapping) – Select the checkbox to activate relay mapping for Secondary Input
loss of lock alarm.
C/N Margin – Choose the alarm condition from the drop-down menu to be activated when the Carrier-to-Noise
margin, set below, is exceeded (Set Alarm /No Alarm).
C/N Margin (min value) – Enter the Carrier-to-Noise margin minimum value in decibels. This is used to trigger the
alarm condition, set above, when exceeded.
C/N Margin (relay mapping) – Select the checkbox to activate relay mapping for C/N Margin exceeded alarm.
Output
IPO Ethernet If 1/2 Down – Choose the alarm condition from the drop-down menu to be activated when there is no
signal at IPO Ethernet 1/2 (Set Alarm /No Alarm).
IPO Ethernet If 1/2 Down (relay mapping) – Select the checkbox to activate relay mapping for no signal at IPO
Ethernet 1/2.
Service
Video Not Running – Choose the alarm condition from the drop-down menu to be activated when video is not
running (Set Alarm /No Alarm).
Video Not Running (relay mapping) – Select the checkbox to activate relay mapping for video not running.