3-83
two VMIM/CIA sets thus providing up to a total of sixty-four
conventional channel interfaces per CEC/IMC. A VMIM is formed by
a Controller Board and up to eight Audio Boards.
VMIM-related channel configurations are performed from the
Site Channel Configuration dialog box. Although not required, it is
recommended that VMIM channel configurations be accomplished
prior to CIA rack-related conventional channel configurations which are
described later in CONVENTIONAL CHANNEL CONFIGURATION
on page 3-145.
VMIM "Site" Selection
Prior to actual channel configuration, the interface module to be
configured must be selected. From the CEC/IMC Manager menu bar
select Configure System / CEC/IMC Configuration / VMIM. When
VMIM is selected two new choices are made available:
Audio Configuration (VMIM audio channel configuration) and
Conv. Interface Adapter Configuration (conventional channel
configuration). Select Audio Configuration to display the
Site Channel Configuration List dialog box for VMIM configuration.
Figure 22 VMIM Configuration Menu
Each Site Channel Configuration List dialog box displays the
configurable "sites" and configured/active "sites." An active "site"
represents an active Controller Board control data link. In the case of a