EQ8096 M-CMTS System Test Specification
10.3.1 System Setup
A tester must perform the following set up when first installing the EQAM
The EQ8096 must have the DTI client card installed. The DTI client can be
either factory fitted or field upgradeable. If necessary, please refer to Chapter 9
of the EQ8096 Reference Guide for instructions regarding this field upgrade
process.
M-CMTS license enabled (please contact Ericsson Customer Support)
Power up the EQAM
After the EQAM has booted note the IP address/mask on the front panel and set
up a PC to be in the same subnet.
If you wish to change this IP Address/subnet mask you can do this via the front
panel or alternatively connect the EQAM via a web client, You will be presented
with the following Web GUI, Figure 10.2:
Figure 10.2 Web GUI Home Page
Note: If the DTI client card is not present the “DEPI Configuration” and “DEPI
Statistics” tab will not be present and the DTI card information “DTI Client
Locked: Yes” and “DTI Timestamp: XXXXXXX” under status will not be
present.
10.3.2 M-CMTS Session Setup
The M-CMTS EQAM sessions are configured using the DEPI Configuration WEB
GUI Page.
2/1553-FGC 101 1019 Uen A