Function Description
4/1553-HSC 901 101/2 Uen B 2009-02-27
7
3 Function Description
Some of the functions in the different nodes are common for two or three
nodes, while others are specific for a specific node.
3.1 Common Functions
This section describes functions that are common for at least two of the
nodes.
3.1.1 EDN312, ESN108, EXN104 Fan and Temperature Control
The nodes uses temperature control state for controlling the fans, as
condition for sending temperature related traps, and if the state is TooHigh
- deactivating all the ADSL lines (EDN312 only). The EDN312 will turn off
the LEDs when the temperature reaches 85° C.
The ADSL lines are stopped in order to reduce the power consumption and
avoid damage to the IP DSLAM. The high temperature value is probably
caused by fan failure, high environment temperatures, or blocked air
outlets. The lines remain deactivated until the temperature reaches the
Normal state, when they are activated again, and an alarm-ceasing trap is
sent.
The thresholds between the temperature states contain hysteresis, as
depicted in Figure 4 on page 8. Note that under normal operation the
temperature state will change between Low, Normal and High. The fan
control will try to maintain the Normal temperature state.