Ericsson EDN312 Guia do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 11
Function Description
8
4/1553-HSC 901 101/2 Uen B 2009-02-27
Low Normal Low Normal High Normal High TooHigh Normal
State:
Temperature
Node temperature
temperatureTooHigh
Trap
tempTooHighCeasing
Trap
Normal
to Low
Low to
Normal
High or
TooHigh
to
Normal
Normal
to High
High to
TooHigh
Threshold
Figure 4 Temperature States of the Nodes
Table 1 on page 8 lists the thresholds for the different nodes:
Table 1 Temperature Thresholds
Threshold EDN312 (Cº) ESN108 (Cº) EXN104 (Cº)
High to TooHigh 95 95 95
Normal to High 75 75 75
High or TooHigh to Normal 73 73 73
Low to Normal 67 67 67
Normal to Low 65 65 65
Note: The IP DSLAM EDN110 has a threshold value of 105° C for High to
TooHigh.
The temperature is measured in hot spots that can endure very high
temperature. The temperature is measured with one-minute intervals.