LBI-39039
17
3.1.7. External Number Length
These entries allow dialing the EDACS radio ID directly after receiving EZDISA dial tone during inbound calls.
NANLS
EXL
External Number
0 First Digit of EDACS LID
MIN
Minimum length
5
MAX
Maximum Length
5
NANLS
EXL
External Number
1 First Digit of EDACS LID
MIN
Minimum length
5
MAX
Maximum Length
5
NANLS
EXL
External Number
2 Prefix for EDACS GID
MIN
Minimum length
5
MAX
Maximum Length
5
NANLS
EXL
External Number
3 Prefix for Digital EDACS LID or GID
MIN
Minimum length
6
MAX
Maximum Length
6
This entry is used in North America for 911, which the LCR ENT table exits from LCR and forwards to Number
Analysis.
NANLS
EXL
External Number
690911 Public Network Destination code + 911
MIN
Minimum length
6
MAX
Maximum Length
6