Menu title: SET:GPO X Description Section
Off - An error on Audio 2 will not trigger this
GPO.
Default = Off.
Data Error:
On - This GPO will be triggered if any of the
Data Alarm conditions detailed in Annex D,
Alarm Categories and Conditions occur.
Off - A data error will not trigger this GPO.
Default = Off.
Annex D
BER Exceeded: *
On - This trigger will be activated if the BER
exceeds 1 X10
-4
.
Off – A BER Exceeded error will not trigger
this GPO.
Default = Off.
Note: * This item will only appear if a QPSK
input module is fitted in the receiver.
----
C.5.19 RS232 Menu
The RS232 setup menu allows the user to enter the configuration of the two RS-232
ports on the unit, the remote port and the LS data port.
Table C.27: RS232 Setup Menu
Menu title: SET:RS232 Description Section
Remote Port > Enters the Remote Port setup submenu. C.5.20
LS Data > Enters the LS Data setup submenu. C.5.21
C.5.20 Remote Port Menu
Caution!
When software upgrading the unit via RS-232 and the Ericsson software upgrade
application (UPGRADE.EXE), it is important that the baud rate is set to 38400, the
data bits to 8, the stop bits to 1, the parity to none, and the flow control to none. If
this is not the case, the UPGRADE software may fail to work.
The remote port menu contains the parameters that have to be configured for a
remote control computer / device to work correctly.
Note: Ericsson remote control or software upgrade software requires the use of a
null-modem (crossed) RS-232 cable.
EN/LZT 790 0002/2 R1A
C-28