Introduction
1.3.2.2 nCompass Control / Web Browser (ETHERNET port)
The receiver must have its IP Address and Subnet Mask (in the
Properties:Network menu) configured to conform to the controlling network. The
receiver can then be controlled using web browser or Ericsson nCompass Control
software.
The unit must be set to ‘local’ control to use either of these modes.
1.3.2.3 Remote (RS-232 REMOTE port)
This state is entered when the Ctrl Mode setting (in the Setup:Control menu) is set
to remote. Local mode commands are ignored when the unit is in Remote mode.
1.3.2.4 Director
When Director is enabled (via software license), the TT1222 Receiver can be put
into Director OAC control mode. This is done by selecting Over Air Control (OAC)
for the Ctrl Mode in the Setup: Control menu.
Note: Local mode is the factory default for the Receivers, even when they are
used in a Director system. To switch to Director OAC mode, refer to
Chapter 5, Operating the Equipment remotely.
When in OAC control mode, all Front Panel, Web Browser (and nCompass Control)
and Serial Remote commands are ignored except the operating mode. The TT1222
can be put into a local lockout condition to also ignore the operating mode
command. When in this condition, there are two ways to recover control:
• Cancelling the local lockout using an over-air command.
• Entering a PIN number via the Conditional Access menu on the Front Panel.
Either of these actions will put the Receiver out of local lockout mode.