Alarm Categories and Conditions
D.4 CA and PSI/SI Related Errors
D.4.1 CA Related Alarms
The CA status alarms indicate the current condition of the CA system
Table D.7: CA Related Alarm Categories and Conditions
Alarm
Category
Contents
Alarm Description Remedy Default
CA system:
No access
The DVB common
interface module has no
access to the currently
selected component.
Check
conditional
access
entitlements with
service provider.
W
D.4.2 PSI/SI Related Alarms
Contains information about the currently processed PSI/SI arriving at the Decoder.
Table D.8: PSI/SI Related Alarm Categories and Conditions
Alarm
Category
Contents
Alarm Description Remedy Default
No stream
input
No stream is detected.
Check input
signal and verify
source.
A
PAT not
present
No data is received on
the PAT PID.
Check input
signal and verify
source.
A
CAT not
present
No data is received on
the CAT PID.
Check input
signal and verify
source.
A
PMT not
present
No data is received on
the PMT PID.
Check input
signal and verify
source.
A
NIT not
present
No data is received on
the NIT PID.
Check input
signal and verify
source.
A
PSI/SI:
SDT/BAT
not present
No data is received on
the SDT or BAT PID.
Check input
signal and verify
source.
A