Front Panel LCD Menus
C.5.21 LS Data Menu
The LS data menu configures the parameters for the output of RS-232 data,
extracted from the transport stream.
Table C.29: LS Data Setup Menu
Menu title: SET:LS DATA Description Section
Mode:
Sets the operation mode of the Asynchronous
data output.
Off - No data is output on the port.
Manual - The data from the PID selected in
the AUX PID menu is output on the port.
Diagnostic - The diagnostic information from
the unit is output on the port.
Default = Off.
----
Aux PID:
Selects the PID that is output on the port if
“Mode” is set to manual.
Default = 0016.
----
Buff Use %:
Shows the fill level of the RS-232 buffer. If this
buffer cycles up to 100% constantly, it is likely
that data is being lost due to buffer overruns.
Note: This is a status item and cannot be set
by the user.
----
Data Port > Enters the Data Port submenu C.5.22
Profile:
Selects the encoding format used by
encoder/transmitter.
Streamed - DVB format.
Piped – Ericsson Proprietary format
Format #2 - Ericsson Proprietary format
TS-Packets - The whole Transport packet
payload
PES Payld - The whole PES packet payload
Default = Streamed.
----
LS Output > Enters the LS Data Output submenu C.5.23
The RS-232 data output cannot exceed the data rate configured in the
communication menu. If the outgoing data rate is higher, information will be dropped
in an unpredictable fashion.
The transmitted PID’s contents should have a lower rate than 115200 bps, since this
is the maximum output rate. If the rate is higher, burst mode can be used, as
explained in Section C.5.23.
EN/LZT 790 0002/2 R1A